The manufacturer provides a complete OPGW strain clamp, including strain clamp, pre-twisted wire protection wire, grounding wire
and necessary connection fittings. The tension clamp should be of pre-stranded wire type, and should be able to withstand at least 95%
of the ultimate tensile strength of the optical cable. The end of the pre-twisted wire protection line should be round and slippery and
slightly upturned. Contains the following accessories:
U-shaped hanging ring-———-Hot-dip galvanized steel U-shaped hanging ring, which plays the role of connecting with the pole tower fastener.
PD hanging plate————-Hot-dip galvanized precision casting PD hanging plate, plays the role of connecting the U-shaped connecting ring
and U-shaped hanging ring, and avoids the exit of the tension clamp The fiber optic cable is too close to the tower to ensure that the fiber
optic cable has a large enough bending radius here.
Insert ring——-Hot-dip galvanized precision cast steel insert ring, which is clamped in the U-shaped bending head of the tension clamp to
protect the tension clamp and connect with the extension.
The protective thread pre-twisted wire is made of galvanized steel wire or aluminum-clad steel wire. The inner wall of the pre-twisted wire
is glued with a layer of fine emery to increase the friction. The pre-twisted wire is pre-formed into four sub-bundles during processing in the
factory to avoid installation errors and facilitate quick installation. The ends of the pre-twisted wires are bent radially outward to avoid
squeezing and damaging the optical cable.
Tensile pre-twisted wire—made of galvanized steel wire or aluminum-clad steel wire. The pre-twisted wire is preformed into bundles during
processing in the factory, and a layer of firm emery is adhered to the inner wall to achieve the Increase the grip strength of the tension clamp
under the condition of reducing the side pressure of the optical cable.
OPGW strain clamp, factory direct sales.
The tension clamp is suitable for the tension tower of the line. In order to ensure the integrity and reliability of the tension clamp function,
in principle, the pre-twisted wire clamp can only be used for a permanent and safe use, and it is generally not allowed to use it repeatedly.
Unless it is only used as a “towing fixture” to tow the optical cable. In order to ensure good performance and personal safety, it is necessary
to clarify whether the model and specifications of the fittings are consistent with the requirements of the optical cable before use.
Although OPGW cable has high mechanical strength, incorrect cable installation can still cause damage to the cable. To avoid twisting and
twisting of optical cables, dynamic bending should not be less than 40 times the cable diameter, that is, to ensure that there is a bending
radius of at least 600mm during construction, and be careful not to be twisted at all times. Any damage will affect the service life and
transmission characteristics of the optical cable. When the OPGW cable is to be tightened, only special fittings, fixtures and devices can
be used. For this project, we require the use of pre-twisted wires to increase the force-bearing area, increase friction, and reduce the
movement of the outer strands.
OPGW optical cable tension-resistant series connection type installation.
(1) Use pre-twisted wire tension clamp.
(2) All kinds of bolts and nails on the hardware string should be uniformly threaded except for the fixed ones.
(3) The down-run of the optical cable connector should be natural, smooth and beautiful.
(4) The grounding lead should be installed at a uniform position across the entire line, and the grounding lead should be natural, smooth
and beautiful.
1) When winding the pre-twisted wire, ensure that both ends are neat and keep the original pre-twisted shape.
(2) The threading direction of various bolts and pins meet the requirements, and the cotter pin double-opening should be 60°~90°.
(3) The optical cable lead and grounding wire should be led out naturally, the lead should be naturally smooth, the direction of the grounding
and groove clamp should not be twisted, or be vertical or horizontal, and the bolt tightening should meet the torque requirements.
(4) The repeated use of the tension-resistant pre-twisted wire of the optical cable shall not exceed two times.
Post time: Sep-10-2021