Good User Reputation for 15kv 100A/200A Polymer Expulsion Fuse Cutout

Short Description:


Product Detail

Product Tags

Dedicated to strict quality management and considerate client company, our experienced team associates are generally available to discuss your demands and make certain full purchaser pleasure for Good User Reputation for 15kv 100A/200A Polymer Expulsion Fuse Cutout, As an experienced group we also accept tailored orders. The main aim of our corporation is always to develop a satisfying memory for all shoppers, and set up a long-term win-win business partnership.
Dedicated to strict quality management and considerate client company, our experienced team associates are generally available to discuss your demands and make certain full purchaser pleasure for China Fuse Cutout and Outdoor Fuse Cutout, With the support of our highly experienced professionals, we manufacture and supply best quality products and solutions. These are quality tested at various occasions to ensure only flawless range is delivered to customers, we also customize the array as per the require of customers to meet the requirement of customers.
Drop type fuse cutouts are outdoor high voltage protection facilities. The fuse is installed at high voltage side of transformer or branch line of distribution line to protect transformer or transmission line from short circuit and overload, to break and connect load current.

Fuse cutout consist of insulation bracket and fuse tube, fixed contact is installed at both ends of insulation bracket, moving contact is installed at both ends of fuse tube. Fuse tube consist of two parts, arcing extinguish tube in inner side and epoxy glass tube outside. Tension load fuse cutout increase the flexible auxiliary contact and arcing-extinguish shield to break or connect load current.

Drop type fuse cutout is a low cost line protection, primarily used on remote overhead electrical transmission lines. The visual display of the status of the fuse cutout quickly and accurately helps field inspectors to locate the faulty segment of the overhead transmission line. Upon clearing of the line fault and replacing the fuse link, each of the phases can then be individually switched back into operation using operating poles, which are available in desired lengths.

1Service condition:

a) The ambient air temperatures: -40 to 40℃
b) The altitude above sea level: 1000m.
c) Wind speed doesn’t exceed 700Pa (not exceed 34m/s)
d) The earthquake intensity doesn’t exceed 8 degrees.

2The product is not applicable to the following locations:

a) Combustion or explosion risk areas.
b) With severe vibration or shock sites.
c) A conductive, chemical gas and serious pollution, salt fog area.

Drop Type Fuse Cutout (1)

11-15kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

YJF-1

12

100

6300

110

40

250

6.5

40×36
×11.5

YJF-1

12

200

10000

110

40

250

6.5

 

11-15kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

YJF-2

15

100

8000

125

45

320

7.5

50×36
×12.5

YJF-2

15

200

12500

125

45

320

7.5

 

11- 15KV( F)

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

YJF2(F)-2

15

100

8000

125

45

320

8

58×40
×15

YJF2(F)-2

15

200

12500

125

45

320

8

 

24kV-27kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

YJF-3

24

100

8000

150

65

530

12

50×38
×16

YJF-3

24

200

12500

150

65

530

12

 

8c534f5c.1

Fuse Cutout Series 12-36kV

33kV-36kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

YJF-4

33

100

8000

170

70

720

15

64×35
×18

YJF-4

33

200

12500

170

70

720

15

 

11kV-15kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

YJF-5

12

100

6300

110

40

250

6.5

40×36
×11.5

YJF-5

12

200

10000

110

40

250

6.5

 

24kV-27kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

YJF-6

24

100

8000

150

65

540

10

60×38
×16

YJF-6

24

200

12500

150

65

540

10

 

11- 15KV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

HYJF-2

15

100

6300

110

40

250

6

40×36
×11.5

HYJF-2

15

200

10000

110

40

250

6

 

16ee4547.2

Fuse Cutout Series 12-36kV

11- 15KV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

HYJF-2

15

100

6300

110

40

250

6

40×38×16

HYJF-2

15

200

10000

110

40

250

6

 

24-27kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

HYJF-3

24

100

8000

150

65

530

7

50×38×16

HYJF-3

24

200

12500

150

65

530

7

 

33-36kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

HYJF-4

33

100

8000

125

45

320

7.5

50×38×12.5

HYJF-4

33

200

12500

125

45

320

7.5

 

24kV-27kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

HYJF-3

24

100

8000

150

65

540

7

50×38×16

HYJF-3

24

200

12500

150

65

540

7

 

799fd0a0.3

33-36kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

HYJF-4

33

100

8000

170

70

720

8

64×36
×18

HYJF-4

33

200

12500

170

70

720

8

 

24kV-27kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

HYJF-7

24

100

8000

150

65

540

10

50×36
×16

HYJF-7

24

200

10000

150

65

540

10

 

33kV-36kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

HYJF-8

33

100

10000

170

70

720

15

64×35
×18

HYJF-8

33

200

12500

170

70

720

15

 

12kV

Item No.

Rated Voltage (kV)

Rated Current (A)

Breaking Current (A)

Impulse Voltage (BIL)

Power Frequency Withstand Voltage

Leakage Distance (MM)

Weight (KG)

Dimension (CM)

RW11

12

100

6300

110

42

260

7.5

48×32
×27

RW11

12

200

8000

110

42

260

7.5

 

799fd0a0.4全球搜详情_03Q:CAN YOU HELP US IMPROT AND EXPORT?

A:We will have a professional team to serve you.

Q:WHAT’S THE CERTIFICATES DO YOU HAVE?

A:We have certificates of ISO,CE, BV,SGS.

Q:WHAT’S YOUR WARRANTY PERIOD?

A:1 year in general.

Q:CAN YOU DO OEM SERVICE?

A:YES,we can.

Q:WHAT YOU LEAD TIME?

A:Our standard models are in stock ,as for big orders ,it take about 15 days.

Q:CAN YOU PROVIDE FREE SAMPLES?

A:Yes,please contact us to know the sample policy.

Dedicated to strict quality management and considerate client company, our experienced team associates are generally available to discuss your demands and make certain full purchaser pleasure for Good User Reputation for 15kv 100A/200A Polymer Expulsion Fuse Cutout, As an experienced group we also accept tailored orders. The main aim of our corporation is always to develop a satisfying memory for all shoppers, and set up a long-term win-win business partnership.
Good User Reputation for China Fuse Cutout and Outdoor Fuse Cutout, With the support of our highly experienced professionals, we manufacture and supply best quality products and solutions. These are quality tested at various occasions to ensure only flawless range is delivered to customers, we also customize the array as per the require of customers to meet the requirement of customers.


  • Previous:
  • Next:

  • Write your message here and send it to us